AS-KIPPE

Ces volets de rinçage (pour cuves) sont parmi les dispositifs les plus efficaces et les plus économiques concernant le nettoyage des boues décantées à partir des bassins de décantation. Ces volets de rinçage sont réglés de telle manière que la cuve peut à n'importe quel moment être rincée automatiquement immédiatement après sa vidange…

Flushing shutters (tubs) are among the most efficient and most economical devices for cleaning settled sludge from settlement tanks. Flushing shutters are set in such a way that the tank can always be automatically flushed immediately after its emptying.

Functional description

The shutter that is eccentrically suspended on bearings is filled with pumped water from an internal or external source. The shutter is overturned due to a change of its point of gravity just before its filling. The water stream then produces a strong wave whose flushing power is used to clean the tank and wash out the sediments to the drain pit.

Structural design

All parts of the flushing shutter (tub, pivots, consoles, and lubricators), except the bearings and stops, are made of stainless steel 1.4301 (X5CrNi 18-10).

Characteristics and advantages

• Flushing is the most economical method of removing deposits
• The flushing shutter is a simple and reliable device
• Strong flushing dynamics
• Balanced, fine, and silent movement
• Flushing length up to 80 m
• Max. width of one section is 6 m
• Lightweight stainless steel structure without any maintenance requirements

Dimensions of the AS-KIPPE type range

Shutter volume Shutter diameter Pivot length from the tank front Pivot depth from the tank edge Weight at the section width of 6 m
V [l/bm] D [m] Lp [mm] Hp [mm] M [kg]
AS-KIPPE/ 200 200 0,550 610 380 281
AS-KIPPE/ 300 300 0,590 650 400 306
AS-KIPPE/ 400 400 0,665 730 430 355
AS-KIPPE/ 500 500 0,740 810 470 406
AS-KIPPE/ 600 600 0,820 900 510 464
AS-KIPPE/ 700 700 0,885 970 540 514
AS-KIPPE/ 800 800 0,940 1 030 570 558
AS-KIPPE/ 900 900 1,000 1 100 600 607
AS-KIPPE/ 1000 1 000 1,052 1 160 630 652
AS-KIPPE/ 1100 1 100 1,104 1 210 650 699
AS-KIPPE/ 1200 1 200 1,152 1 270 680 743
AS-KIPPE/ 1300 1 300 1,200 1 320 700 789
AS-KIPPE/ 1400 1 400 1,245 1 370 720 833
AS-KIPPE/ 1500 1 500 1,300 1 430 750 890
AS-KIPPE/ 1600 1 600 1,355 1 490 780 948
AS-KIPPE/ 1700 1 700 1,410 1 550 810 1 009
AS-KIPPE/ 1800 1 800 1,465 1 610 830 1 071

Identification

AS - KIPPE/ xxx/ yyyy/ Z 

xxx .... Required volume in l/lm (300 – 1,500 l/bm)
yyyy ... Width of one section in mm (max. 6,000 mm)

Operation automation

The standard delivery contains the flushing shutter, including complete anchorage. For the automation of the flushing process, the standard delivery can be supplemented with the automatic filling of the shutter, setting the number of flushing cycles, an acoustic alarm before the overturning. The level of automation depends on the customer’s requirements.

Shutter type selection

The selection is based on the required storage volume. This volume is used to determine the dimensions and type of the device. The calculation should consider the storage height (min. 2 m) and the width of one section (max. 6 m); the length of the tank is then selected accordingly. The length of the tank then determines the selection of the suitable equipment type, i.e., the volume of the flushing shutter per 1 linear metre (lm).
Example: You need to store the volume V 2,200 m 3 . Select the width B 12 m, i.e., considering the depth Hv 4 m, the length of the tank L is approx. 45 m. The required volume of the tub, 1,000 l/lm then corresponds to the length of the route. Thus you should select 2x the AS-KIPPE 1,000/ 6,000/ M type

Requirements for the construction part

The tub is suspended on bearings seated on brackets that are attached to the tank walls. The consoles are anchored to the walls with stainless-steel anchors. The inner distance of the walls is generally 6 mm; equipment with a different width can be delivered on request. The front wall of the tank is rounded such that the stream can be directed without a loss of dynamics and the gradient of the bottom is at least 2%. The sump volume at the end of the tank should be at least 1.25 times the shutter volume. The tanks can me designed as closed or open. With open tanks, it is necessary to solve the possibility of winter operation.

Price

We will be happy to personally inform you about the prices of individual shutter types on your request.

References

5x AS-KIPPE/ 600/ 5,700/ M, town: Plzeň CZ
4x AS-KIPPE/ 2,000/ 6,300/ M, town: Plzeň, CZ
1x AS-KIPPE/ 300/ 5,700/ M, town: Plzeň, CZ
1x AS-KIPPE/ 200/ 4,000/ M, town: Vìžky, CZ
1x AS-KIPPE/ 500/ 5,000/ M, town: Slavkov, CZ
1x AS-KIPPE/ 300/ 4,500/ M, town: Rousínov, CZ
1x AS-KIPPE/ 200/ 6,800/ M, town: Příbram, CZ
8x AS-KIPPE/ 1,100/ 6,000/ M, town: Graz, A 
1x AS-KIPPE/ 1,100/ 6,000/ M, town: Tušimice, CZ
2x AS-KIPPE/ 500/ 4,500/ M, town: Zubří, CZ
4x AS-KIPPE/ 1,000/ 10,000/ M, town: Karviná, CZ
1x AS-KIPPE/ 400/ 8,000/ M, town: Karviná, CZ
2x AS-KIPPE/ 500/ 6,000/ M, town: Hustopeče, CZ
2x AS-KIPPE/ 300/ 4,900/ M, town: Podivín, CZ
4x AS-KIPPE/ 1,000/ 3,000/ M, town: Břeclav, CZ
1x AS-KIPPE/ 500/ 5,250/ M, town: Mikulov, CZ
1x AS-KIPPE/ 500/ 2,900/ M, town: Mikulov, CZ
1x AS-KIPPE/ 400/ 4,800/ M, town: Valtice, CZ
2x AS-KIPPE/ 700/ 2,000/ M, town: Valtice, CZ