AS–REWA fr
Réservoirs en plastique pour le stockage et l’utilisation ultérieure des eaux de pluie…
Réservoirs en plastique pour le stockage et l’utilisation ultérieure des eaux de pluie…
Plastic tanks for the storage and subsequent use of rainwater. Due to various roof shapes and coverings, not all rainwater is drained off the roof. This is expressed by the “drainage coefficient” (0.6 to 0.8). When rainwater comes in contact with the roof, it may get contaminated, and therefore not all roofs are equally suitable for the collection of rainwater.
Due to various roof shapes and coverings, not all rainwater is drained off the roof. This is expressed by the “drainage coefficient” (0.6 to 0.8). When rainwater comes in contact with the roof, it may get contaminated, and therefore not all roofs are equally suitable for collection of rainwater.
Rain - falling on built-up areas is usually drained into the sewerage system without being used in any manner. The amount of water is not the same in all areas. It is expressed by the average annual amount of precipitation in mm/year, which indicates how many mm of precipitation (“rain”} per 1 m 2 per year, in a particular area. 1 mm of precipitation is equivalent to 1 l of water.
The “production” of rainwater is 500 - 800 l per 1 m 2 per year.
Breakdown of household water consumption
Average amount of precipitation in mm/year:
Prague 570; Brno 660; Olomouc 680; Ostrava 750; Plzeň 670
Gutter and gutter pipes – drain captured rainwater from the roof.
Filter – removes mechanical dirt from rainwater (e.g., leaves). It must have a corresponding efficiency and self-cleaning capability.
Tank pipeline – directs treated water to the tank.
Tank – above-ground or underground, accumulates rainwater; it should maintain a temperature below 16°C to limit the propagation of bacteria (underground tanks are convenient); it must have adequate strength and the inlet arranged in such a way that the dirt on the bottom should not be whirled up; it must have a safety overflow.
Replenishing unit – adds potable water to the system in dry periods. It must ensure the separation of the distribution systems of potable water and rainwater.
Pump with a pressure switch or domestic pumping station – maintains the pressure of rainwater in the system.
Rainwater distribution system – transports rainwater to the places of consumption; it must be separated from the potable water distribution system.
Safety overflow – drains water if the tank gets overfilled.
Pipeline to the sewerage system – drains part of the water with the mechanical dirt.
Sewerage system – drains excess rainwater or alternatively infiltration with the use of an AS–NIDAPLAST block.
In a single unit it ensures:
It is delivered in standard sizes with an accumulation volume of 1.0 to 8.8 m 3 .
Tank design options:
TYPE |
Accumulation
volume [m 3 ] |
Tank design | Tank shape |
External dimensions *
[m] |
Weight
[kg] |
AS-REWA Kombi 1EO | 1,00 | Jacketed self-supporting | Cylindrical | 0,95 x 1,51 | 100 |
AS-REWA Kombi 2EO | 2,00 | Jacketed self-supporting | Cylindrical | 1,40 x 1,51 | 130 |
AS-REWA Kombi 3EO | 2,84 | Jacketed self-supporting | Cylindrical | 1,65 x 1,51 | 150 |
AS-REWA Kombi 4ER | 3,64 | Jacketed self-supporting | Rectangular | 2,00 x 1,16 x 2,16 | 450 |
AS-REWA Kombi 5ER | 4,66 | Jacketed self-supporting | Rectangular | 3,16 x 1,00 x 2,16 | 600 |
AS-REWA Kombi 6ER | 6,20 | Jacketed self-supporting | Rectangular | 4,16 x 1,00 x 2,16 | 750 |
AS-REWA Kombi 8ER | 7,96 | Jacketed self-supporting | Rectangular | 2,50 x 2,00 x 2,16 | 820 |
AS-REWA Kombi 4EO/PB | 3,80 | Double-jacketed | Cylindrical | 2,01 x 2,00 | 600 |
AS-REWA Kombi 5EO/PB | 4,90 | Double-jacketed | Cylindrical | 2,24 x 2,00 | 660 |
AS-REWA Kombi 6EO/PB | 5,70 | Double-jacketed | Cylindrical | 2,47 x 2,00 | 800 |
AS-REWA Kombi 8EO/PB | 8,80 | Double-jacketed | Cylindrical | 2,47 x 3,00 | 1000 |
* Cylindrical tank = diameter x height without the inlet shaft, inlet shaft height = 0.7 m
Rectangular tank = length x width x height, height without the inlet shaft, inlet shaft height = 0.7 m
TYPE |
Accumulation
volume [m 3 ] |
Tank design | Tank shape |
External dimensions *
[m] |
Weight
[kg] |
AS-REWA 1EO ECO | 1,00 | Jacketed self-supporting | Cylindrical | 0,95 x 1,50 | 100 |
AS-REWA 2EO ECO | 2,00 | Jacketed self-supporting | Cylindrical | 1,40 x 1,50 | 130 |
AS-REWA 3EO ECO | 2,84 | Jacketed self-supporting | Cylindrical | 1,65 x 1,50 | 150 |
AS-REWA 4EO ECO | 3,64 | Jacketed self-supporting | Cylindrical | 1,80 x 1,50 | 170 |
AS-REWA 5EO ECO | 4,66 | Jacketed self-supporting | Cylindrical | 1,90 x 1,50 | 190 |
* Composite flue for all the above-mentioned types 600 x 600 x 300 mm
The price comprises: A cylindrical PP tank, gravity filter, inlet flue 300 mm, safety overflow, composite cover 600 x 600 mm
The price does not comprise: a pump, electric installation.
TYPE | Accumulation volume [m 3 ] | External dimensions * [m] | Weight [kg] |
AS–REWA 1EO tank | 1,00 | Ø 1,20 x 1,51 | 70 |
AS–REWA 2EO tank | 2,00 | Ø 1,40 x 1,51 | 98 |
AS–REWA 3EO | 2,84 | Ø 1,65 x 1,51 | 120 |
* … Diameter x height without the inlet shaft; inlet shaft height = 0.3 m
TYPE | Accumulation volume [m 3 ] |
External dimensions *
[m] |
Weight
[kg] |
AS–REWA – 4EO/PB tank | 3,8 | Ø 2,01 x 2,00 | 600 |
AS–REWA – 5EO/PB tank | 4,9 | Ø 2,24 x 2,00 | 660 |
AS–REWA – 6EO/PB tank | 5,7 | Ø 2,47 x 2,00 | 800 |
AS–REWA – 8EO/PB tank | 8,8 | Ø 2,47 x 3,00 | 1000 |
* … Diameter x height without the inlet shaft; possible inlet shaft height = 0.2 to 3 m